{"id":1452,"date":"2026-07-09T19:03:24","date_gmt":"2026-07-09T11:03:24","guid":{"rendered":"https:\/\/www.htn-ti.com\/how-to-read-and-verify-a-mill-test-certificate-mtc-for-medical-titanium-materials"},"modified":"2026-10-18T22:59:07","modified_gmt":"2026-10-18T22:59:07","slug":"how-to-read-and-verify-a-mill-test-certificate-mtc-for-medical-titanium-materials","status":"publish","type":"post","link":"https:\/\/www.htn-ti.com\/fr\/how-to-read-and-verify-a-mill-test-certificate-mtc-for-medical-titanium-materials\/","title":{"rendered":"How to read and verify a Mill Test Certificate (MTC) for medical titanium materials"},"content":{"rendered":"<p><!-- seo-keyword: How to read and verify a Mill Test Certificate (MTC) for medical titanium materials -->\n<link href=\"https:\/\/m2cdn.fastindexs.com\/npmanager\/static\/lib\/ckeditor5\/preview.css?v=1.3.053\" rel=\"stylesheet\" \/>\n<style>\n.seo-article{line-height:1.75;font-size:15px;color:#222}\n.seo-article p{margin:0 0 12px}\n.seo-article h1{margin:6px 0 14px;font-size:24px}\n.seo-article h2{margin:20px 0 8px;font-size:20px}\n.seo-article h3{margin:14px 0 6px;font-size:17px}\n.seo-article ul,.seo-article ol{margin:8px 0 12px 22px}\n.seo-article li{margin:4px 0}\n.seo-article table{border-collapse:collapse;width:100%;margin:14px 0}\n.seo-article th,.seo-article td{border:1px solid #ccc;padding:8px 10px}\n<\/style>\n<div class=\"seo-article\">\n<h1>How to read and verify a Mill Test Certificate (MTC) for medical titanium materials<\/h1>\n<p>Medical devices implanted in the human body leave no room for guesswork. A hip stem, a spinal cage, a bone screw\u2014each component must perform flawlessly for decades. Yet the raw titanium that goes into these implants often travels across multiple countries before it reaches a machine shop. The only document that closes the accountability loop between the melt shop and the operating room is the Mill Test Certificate. Learning to read and verify an MTC for medical titanium materials is not just a paperwork drill. It is a hard engineering discipline that prevents mixed grades, non\u2011conforming chemistry, and ultimately, patient harm. In the sections that follow, we will pull apart a typical certificate section by section, call out the numbers that matter most, and show how a systematic verification routine catches the errors that spreadsheets miss.<\/p>\n<h2>The document that carries the entire quality chain<\/h2>\n<p>An MTC\u2014sometimes labeled an inspection certificate, a 3.1 or 3.2 per EN 10204\u2014summarises the production route and test results for a specific batch of metal. For medical\u2011grade titanium the stakes are especially high because mechanical failure is not the only risk. Even a slight shift in interstitial element content can change the material\u2019s response to the body\u2019s environment. A single incorrectly verified heat can force a production line into quarantine, scrap a lot of finished parts, or trigger a costly regulatory re\u2011submission if it reaches a notified body. Shaanxi Huatainuo Metal Co., Ltd. works to international frameworks including AMS, ASTM, ASME, ISO, DIN and JIS, and its quality management system is certified to ISO 9001 and ISO 13485 for titanium and titanium alloy materials. Those certifications become real only when the paper they produce is read correctly.<\/p>\n<h2>Before you open the certificate: three things that must already be on your desk<\/h2>\n<p>Start the verification with the purchase order and the prevailing material standard, not with the MTC itself. If you do not know what you ordered, you cannot confirm what you received. Pull up three items:<\/p>\n<ul>\n<li>The purchase specification, which states the grade (e.g., Grade 5 ELI per ASTM F136 or Grade 23 per ASTM F136), the required form (bar, wire, sheet), and the condition (annealed, hot\u2011finished).<\/li>\n<li>The referenced standard\u2019s latest revision. ASTM F136 was reapproved as recently as 2019; ISO 5832\u20112 and ISO 5832\u20113 are regularly updated. Working from an outdated edition will make you reject conforming material or accept non\u2011conforming material.<\/li>\n<li>The mill\u2019s quality system credentials. Confirm that the certifying laboratory is accredited to ISO\/IEC 17025 for the specific test methods quoted.<\/li>\n<\/ul>\n<p>Lay these documents side by side. Verification starts with alignment.<\/p>\n<h2>Reading the header block: heat number, order number, and traceability anchors<\/h2>\n<p>Every MTC begins with a header. This is where most casual reviews stop, and that is a mistake. The header contains the coordinates that link the physical material to the quality system. Check each field against your receiving log.<\/p>\n<p>The heat number (also called a cast or lot number) is the single most important identifier. It must match the number physically marked on the product. For <strong><em><a href=\"https:\/\/www.htn-ti.com\/fr\/product-category\/titanium-bar\/\" style=\"color: #0563C1;\">Titanium Bar<\/a><\/em><\/strong>, the heat number is typically ink\u2011jetted, stamped, or laser\u2011engraved on one end of each bar. For <strong><em><a href=\"https:\/\/www.htn-ti.com\/fr\/product-category\/titanium-wire\/\" style=\"color: #0563C1;\">Titanium Wire<\/a><\/em><\/strong>, especially fine\u2011diameter coils, the number might appear on a tag firmly attached to the coil. For <strong><em><a href=\"https:\/\/www.htn-ti.com\/fr\/product-category\/titanium-sheet\/\" style=\"color: #0563C1;\">Titanium Sheet<\/a><\/em><\/strong>, you will find it stencilled on the surface or on a protective label. If the field is blank or the number differs from the physical marking by even one digit, stop. No further testing can compensate for lost traceability.<\/p>\n<p>Other header fields to verify:<\/p>\n<ul>\n<li><strong>Supplier name and address<\/strong> \u2013 must match the approved vendor on your qualified supplier list.<\/li>\n<li><strong>Purchase order number<\/strong> \u2013 confirms the lot was produced against your specific contract, not taken from general stock.<\/li>\n<li><strong>Standard and grade designation<\/strong> \u2013 should read exactly as ordered, for instance \u201cASTM F136 Grade 23 (Ti\u20116Al\u20114V ELI)\u201d or \u201cISO 5832\u20112 Grade 4 unalloyed titanium.\u201d<\/li>\n<li><strong>Product form and dimensions<\/strong> \u2013 bar diameter, wire gauge, or sheet thickness, together with the relevant dimensional tolerance standard (ASTM B348, ASTM F67, etc.).<\/li>\n<li><strong>Quantity and weight<\/strong> \u2013 cross\u2011reference with the packing list; any mismatch here often signals a data\u2011entry error or a partial shipment.<\/li>\n<\/ul>\n<h2>Chemical composition: the blueprint of biocompatibility<\/h2>\n<p>The chemical limits for medical titanium are narrow by design. Vanadium, aluminium, and trace iron all influence whether an oxide layer will remain stable inside the body. Oxygen and nitrogen control the transition from ductile to brittle behaviour. This section of the MTC should list the measured value for each controlled element alongside the specification limit. Do not settle for a \u201cpass\u201d or \u201cconforms\u201d note\u2014demand numeric results.<\/p>\n<p>For Grade 23 (Ti\u20116Al\u20114V ELI) under ASTM F136, the maximum allowable oxygen is 0.13%. The standard also caps nitrogen at 0.05%, carbon at 0.08%, hydrogen at 0.012%, and iron at 0.25%. A heat reporting oxygen at 0.14% is out of spec, even if the aluminium and vanadium values sit comfortably within their 5.50\u20136.75% and 3.50\u20134.50% ranges. An oxygen content pushing the upper bound can still cause a dramatic drop in ductility after hot forming or welding. Typical practice in medical device manufacturing is to set internal oxygen limits tighter than the ASTM maximum\u2014often 0.10% or lower for high\u2011fatigue components.<\/p>\n<p>A common error is to read only the major alloying elements. The MTC will also show residual elements such as molybdenum, tin, and copper. Each of these has a permissible ceiling. A tin reading of 0.1% might be reported as \u201cPASS\u201d on an older certificate format, but a careful buyer will check whether the supplier\u2019s melting practice routinely keeps residuals below half the allowed limit.<\/p>\n<table style=\"border-collapse:collapse;width:100%;margin:14px 0;font-size:14px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #ccc;padding:8px 10px;text-align:left;background:#f5f7fa;font-weight:bold\">Element<\/th>\n<th style=\"border:1px solid #ccc;padding:8px 10px;text-align:left;background:#f5f7fa;font-weight:bold\">ASTM F136 Max (wt%)<\/th>\n<th style=\"border:1px solid #ccc;padding:8px 10px;text-align:left;background:#f5f7fa;font-weight:bold\">ISO 5832\u20112 CP Grade 4 Max (wt%)<\/th>\n<th style=\"border:1px solid #ccc;padding:8px 10px;text-align:left;background:#f5f7fa;font-weight:bold\">Typical tight internal target<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">Oxygen (O)<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.13<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.40<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.10<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">Nitrogen (N)<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.05<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.05<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.03<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">Carbon (C)<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.08<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.08<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.05<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">Hydrogen (H)<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.012<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.015<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.008<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">Iron (Fe)<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.25<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.50<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">0.20<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">Aluminium (Al)<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">5.50\u20136.75<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">\u2014<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">\u2014<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">Vanadium (V)<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">3.50\u20134.50<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">\u2014<\/td>\n<td style=\"border:1px solid #ccc;padding:8px 10px;text-align:left\">\u2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Data derived from publicly available standard limits. Internal targets are illustrative ranges based on industry feedback.<\/p>\n<h2>Mechanical properties: the numbers that keep an implant from breaking<\/h2>\n<p>The chemical analysis explains what the material is, but the mechanical section tells you how it will behave under load. Medical titanium alloys are often specified in the annealed condition to maximise elongation and reduce residual stress. Verify that the stated heat treatment matches your requirement. An annealed Ti\u20116Al\u20114V ELI bar should exhibit a minimum tensile strength of 860 MPa, a minimum yield strength of 795 MPa, and an elongation of at least 10% per ASTM F136. For commercially pure Grade 4 wire, the numbers shift\u2014ASTM F67 annealed sheet, for instance, expects a minimum tensile of 550 MPa and elongation of 15%.<\/p>\n<p>If your component will see cyclic loading\u2014a femoral stem, a dental implant abutment\u2014do not stop at static tensile values. Some MTCs include rotating beam fatigue data or KIC fracture toughness values when ordered as supplementary tests. Even when such data are absent, you can infer quite a bit by comparing the yield\u2011to\u2011tensile ratio. A ratio above 0.95 may indicate a material that work\u2011hardens rapidly but shows limited uniform elongation, a concern for cold\u2011forming steps.<\/p>\n<p>Hardness values also appear on many certificates. For Grade 23, Rockwell C values typically fall between 30 and 36 HRC in the annealed state. A reading of 42 HRC would suggest the material was either cold\u2011worked or not fully annealed, a discrepancy worth questioning.<\/p>\n<h2>Supplementary tests: when the standard demands more than tensile data<\/h2>\n<p>Medical titanium MTCs frequently include results beyond chemistry and tensile properties. Depending on the standard and the product form, you might see:<\/p>\n<ul>\n<li><strong>Microstructure assessment<\/strong> \u2013 for Ti\u20116Al\u20114V ELI, ASTM F136 requires a transformed beta or equiaxed alpha\u2011beta structure free of a continuous alpha network at prior beta grain boundaries. A certificate that only states \u201cmicro conforms\u201d without a photomicrograph or a detailed description is insufficient for critical rotating implants.<\/li>\n<li><strong>Ultrasonic testing<\/strong> \u2013 for bars intended for rotating components, ultrasonic inspection per AMS 2631 or an equivalent procedure is often invoked. The MTC must state the acceptance class (e.g., Class A, Class AA) and the reference notch size.<\/li>\n<li><strong>Surface condition<\/strong> \u2013 for <strong><em><a href=\"https:\/\/www.htn-ti.com\/fr\/product-category\/titanium-wire\/\" style=\"color: #0563C1;\">Titanium Wire<\/a><\/em><\/strong> used in fine\u2011wire machining, the presence of a light oxide layer or drawing lubricant residue can affect downstream coating adhesion. The certificate should confirm that the product was supplied in a condition appropriate for the next operation, whether that is cold heading, welding, or coating.<\/li>\n<li><strong>Grain size<\/strong> \u2013 for sheet that will undergo superplastic forming, grain size influences flow stress. ASTM E112 results (often aiming for ASTM grain size number 5\u20139) may appear as a supplementary entry.<\/li>\n<\/ul>\n<h2>Verification checks that connect the paper to the physical metal<\/h2>\n<p>An accurate MTC can still hide a physical mismatch. Perform at least two physical verification steps before accepting the lot.<\/p>\n<p>First, confirm the heat number on the product matches the certificate, as already described. Second, use a handheld X\u2011ray fluorescence (XRF) analyser for a quick alloy verification. XRF won\u2019t give you oxygen or carbon, but it will confirm the titanium\u2011aluminium\u2011vanadium balance to within roughly \u00b10.2%. If your XRF reads 5.0% aluminium on a certificate certified to 6.1%, the gage may be drifting, but a reading of 3.0% aluminium is a clear red flag.<\/p>\n<p>For bars and plates, check one additional dimensional spot. Measure the diameter or thickness in three orientations and compare with the tolerance band on the certificate. A growing body of quality data from industrial buyers shows that dimensional non\u2011conformances correlate with other process lapses roughly 30% of the time\u2014diverted priority, cutting errors, or rushed dispatch. If a batch passes chemistry and tensile but fails a simple calliper check, treat the whole lot as suspect until you have mapped the discrepancy.<\/p>\n<h2>Where good certificates go wrong: frequent verification traps<\/h2>\n<p>Several failure patterns repeat across supply chains. Spotting them early saves days of investigation.<\/p>\n<ul>\n<li><strong>Legacy standard edition<\/strong> \u2013 a certificate referencing \u201cASTM F136\u201108a\u201d when today\u2019s revision is F136\u201119 may hide a relaxation of a sampling frequency or a test requirement that has since been tightened. Ask the supplier to re\u2011issue the certificate against the current edition or provide an engineering justification for the earlier revision.<\/li>\n<li><strong>Averaged results without individual values<\/strong> \u2013 some mills report a single averaged tensile result for multi\u2011strand heats. The standard may permit this under specific conditions, but for medically finished devices, you often want the worst\u2011case value, not the average. Request the raw test reports when the application demands it.<\/li>\n<li><strong>Missing test temperature<\/strong> \u2013 low\u2011temperature impact tests or room\u2011temperature tensile tests must state the test temperature explicitly. A tensile result of 950 MPa without a temperature reference is unverifiable.<\/li>\n<li><strong>Office\u2011processed certificates<\/strong> \u2013 an MTC that lists the physical test date as \u201c24 December\u201d for a test the laboratory says was closed two weeks earlier should raise a documentation integrity flag. Cross\u2011check test dates in the laboratory information system when available.<\/li>\n<\/ul>\n<h2>A practical routine for procurement and quality teams<\/h2>\n<p>Make verifying an MTC for medical titanium materials a staged process rather than a one\u2011person checklist.<\/p>\n<ul>\n<li><strong>Receive stage<\/strong> \u2013 warehouse staff confirm heat numbers, count, and visible damage. They log the MTC into the ERP system and flag any gross mismatches.<\/li>\n<li><strong>Document review<\/strong> \u2013 a materials engineer compares every numeric result against the purchase order and the standard. The reviewer also checks mill accreditation and standard revision.<\/li>\n<li><strong>Physical verification<\/strong> \u2013 XRF check and dimensional sampling. Each check is logged against the heat number.<\/li>\n<li><strong>Acceptance decision<\/strong> \u2013 only after all three stages produce a clean record is the material released for production.<\/li>\n<\/ul>\n<p>When you work with a mill that understands this rhythm, the entire sequence runs faster. Shaanxi Huatainuo Metal Co., Ltd. supplies titanium bar, wire, sheet, tube, foil, alloy 3D\u2011printer consumables and machined parts with full\u2011form MTC packages aligned to ASTM, ISO, and AMS requirements. The company\u2019s quality control follows a comprehensive system built around documented testing, not verbal assurances.<\/p>\n<h2>Answers to the questions buyers keep asking<\/h2>\n<p><strong>Does an MTC prove the material is safe for implants?<\/strong><\/p>\n<p>An MTC proves the material conformed to the stated standard at the time of testing. It does not, by itself, demonstrate biocompatibility for a finished device. That responsibility sits with the device manufacturer, who must conduct additional biocompatibility testing under ISO 10993. The MTC is a prerequisite, not a substitute.<\/p>\n<p><strong>What is the difference between an MTC and a Certificate of Conformance?<\/strong><\/p>\n<p>A Certificate of Conformance (CoC) is a simpler document stating that the product meets the purchase order requirements. It rarely includes numeric test results. An MTC, also called an inspection certificate 3.1 or 3.2, lists actual measured values for chemical composition and mechanical properties, signed by an authorised representative of the mill or an independent inspector.<\/p>\n<p><strong>Why are oxygen and iron limits so much tighter in ELI than in standard Grade 5?<\/strong><\/p>\n<p>Titanium\u20116Al\u20114V ELI (Extra Low Interstitials) was developed specifically for fracture\u2011critical applications. Reducing oxygen and iron lowers the ductile\u2011to\u2011brittle transition temperature and improves fracture toughness at body temperature. For orthopaedic implants that must survive millions of loading cycles, this margin against crack initiation is essential.<\/p>\n<h2>Embedding MTC discipline into your sourcing workflow<\/h2>\n<p>A Mill Test Certificate is more than a delivery note. It is the paper trail that connects a billet of sponge titanium to a sterile\u2011packaged device on a hospital tray. The moment you treat it as a bureaucratic formality, you introduce ambiguity. Ambiguity costs time during audits, money during recalls, and reputation when a quality system fracture becomes public.<\/p>\n<p>Make it standard practice to request a sample MTC from any new titanium supplier before placing the first order. Examine the level of detail, the clarity of the heat number system, and whether the tests quoted match internationally recognised methods. If a supplier hesitates to share a sample certificate, that hesitation is data.<\/p>\n<p>For engineers and buyers handling medical\u2011grade titanium, every decimal point on a chemistry line carries weight. When you hold a <strong><em><a href=\"https:\/\/www.htn-ti.com\/fr\/product-category\/titanium-sheet\/\" style=\"color: #0563C1;\">Titanium Sheet<\/a><\/em><\/strong> in your hand that will become a bone plate, or when a coil of <strong><em><a href=\"https:\/\/www.htn-ti.com\/fr\/product-category\/titanium-wire\/\" style=\"color: #0563C1;\">Titanium Wire<\/a><\/em><\/strong> is threaded into a CNC Swiss lathe to make dental screws, the values on the MTC are the last guarantee before the material disappears into a machined component. Read them as if a patient\u2019s outcome depends on them, because it does.<\/p>\n<p>Moving forward with a verified lot, the next logical step is to lock the approved raw material specification inside your ERP, attach the MTC to the batch history, and share the relevant test data with your notified body if the material goes into a Class III device. That closes the loop from melt practice to regulatory file. With a robust verification process in place, your supply chain gets faster, not slower\u2014because you catch the bad actors before they reach the production floor. For reliable starting material with full documentation, explore the range of <a href=\"https:\/\/www.htn-ti.com\/fr\/product-category\/products\/\">titanium products<\/a> designed for critical applications and supported by a quality system built to medical device standards.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>How to read and verify a Mill Test Certificate (MTC) for medical titanium materials Medical devices implanted in the human body leave no room for guesswork. A hip stem, a spinal cage, a bone screw\u2014each component must perform flawlessly for decades. Yet the raw titanium that goes into these implants often travels across multiple countries [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":860,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1452","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"_links":{"self":[{"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/posts\/1452","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/comments?post=1452"}],"version-history":[{"count":1,"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/posts\/1452\/revisions"}],"predecessor-version":[{"id":1473,"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/posts\/1452\/revisions\/1473"}],"wp:attachment":[{"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/media?parent=1452"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/categories?post=1452"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.htn-ti.com\/fr\/wp-json\/wp\/v2\/tags?post=1452"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}